Option _topBottomCorrection
|
Definitions |
Type |
enum (of string) |
Description: Sets the top/bottom correction.
Theta Z1 can be set only for still images.
Must be one of:
- “Apply”
- Top/bottom correction is performed.
- “ApplyAuto”
- “ApplySemiAuto”
- Top/bottom correction is performed. The parameters used for top/bottom correction for the first image are saved and used for the second and subsequent images.
- Theta X only.
- “ApplySave”
- Performs top/bottom correction and then saves the parameters.
- “ApplyLoad”
- Performs top/bottom correction using the saved parameters.
- “Disapply”
- Does not perform top/bottom correction.
- “Manual”
- Performs the top/bottom correction with the specified front position. The front position can be specified with _topBottomCorrectionRotation.
- Theta X only.
Default correction
Theta X
Shooting method |
performing correction |
Others than multi bracket shooting |
Apply |
Multi bracket shooting |
ApplySemiAuto |
Theta Z1
Shooting method |
performing correction |
Normal shooting |
Apply |
Interval shooting |
ApplySemiAuto |
Fixed interval shooting |
ApplySemiAuto |
Multi bracket shooting |
ApplySemiAuto |